Home Tools
Log in
Cart

KF38789

Catalog No. T22889   CAS 257292-29-8
Synonyms: KF 38789

KF38789 is a selective inhibitor of P-selectin-mediated cell adhesion and P-selectin immunoglobulin G chimeric protein.

All products from TargetMol are for Research Use Only. Not for Human or Veterinary or Therapeutic Use.
KF38789 Chemical Structure
KF38789, CAS 257292-29-8
Pack Size Availability Price/USD Quantity
1 mg In stock $ 53.00
5 mg In stock $ 123.00
10 mg In stock $ 197.00
25 mg In stock $ 376.00
50 mg In stock $ 559.00
Bulk Inquiry
Get quote
Select Batch  
Purity: 98.13%
Purity: 97.29%
Contact us for more batch information
Biological Description
Chemical Properties
Storage & Solubility Information
Description KF38789 is a selective inhibitor of P-selectin-mediated cell adhesion and P-selectin immunoglobulin G chimeric protein.
Targets&IC50 P-selectin-Ig:1.97 microM
In vitro KF 38789, inhibited the binding of U937 cells to immobilized P-selectin immunoglobulin G chimeric protein (P-selectin-Ig) with an IC50 value of 1.97 microM. Cell adhesion to both E-selectin-Ig and L-selectin-Ig were not affected even by 100 microM of KF 38789. Moreover, KF 38789 inhibited P-selectin-induced superoxide production from human polymorphonuclear cells. Intravenously injected KF 38789 significantly inhibited the TG-induced accumulation of leukocytes in the mouse peritoneal cavity (p<0.01)[1].
In vivo KF 38789 significantly reduced mechanical allodynia in the facial carrageenan-injected mice[2].
Synonyms KF 38789
Molecular Weight 375.44
Formula C19H21NO5S
CAS No. 257292-29-8

Storage

Powder: -20°C for 3 years | In solvent: -80°C for 1 year

Solubility Information

DMSO: < 30 mg/mL (79.91 mM)

TargetMolReferences and Literature

1. S Ohta, et al. Inhibition of P-selectin specific cell adhesion by a low molecular weight, non-carbohydrate compound, KF38789. Inflamm Res. 2001 Nov;50(11):544-51. 2. Kay-Wee Poh, et al. Global gene expression analysis in the mouse brainstem after hyperalgesia induced by facial carrageenan injection--evidence for a form of neurovascular coupling? Pain. 2009 Mar;142(1-2):133-41. 3. Peter J Gillies, et al. Demonstration of P-selectin expression and potential function in human corneal epithelial cells. Exp Eye Res. 2018 Nov;176:196-206.

Related compound libraries

This product is contained In the following compound libraries:
Inhibitor Library Bioactive Compound Library Bioactive Compounds Library Max

TargetMolDose Conversion

You can also refer to dose conversion for different animals. More

TargetMol In vivo Formulation Calculator (Clear solution)

Step One: Enter information below
Dosage
mg/kg
Average weight of animals
g
Dosing volume per animal
ul
Number of animals
Step Two: Enter the in vivo formulation
% DMSO
%
% Tween 80
% ddH2O
Calculate Reset

TargetMolCalculator

Molarity Calculator
Dilution Calculator
Reconstitution Calculation
Molecular Weight Calculator
=
X
X

Molarity Calculator allows you to calculate the

  • Mass of a compound required to prepare a solution of known volume and concentration
  • Volume of solution required to dissolve a compound of known mass to a desired concentration
  • Concentration of a solution resulting from a known mass of compound in a specific volume
See Example

An example of a molarity calculation using the molarity calculator
What is the mass of compound required to make a 10 mM stock solution in 10 ml of water given that the molecular weight of the compound is 197.13 g/mol?
Enter 197.13 into the Molecular Weight (MW) box
Enter 10 into the Concentration box and select the correct unit (millimolar)
Enter 10 into the Volume box and select the correct unit (milliliter)
Press calculate
The answer of 19.713 mg appears in the Mass box

X
=
X

Calculator the dilution required to prepare a stock solution

Calculate the dilution required to prepare a stock solution
The dilution calculator is a useful tool which allows you to calculate how to dilute a stock solution of known concentration. Enter C1, C2 & V2 to calculate V1.

See Example

An example of a dilution calculation using the Tocris dilution calculator
What volume of a given 10 mM stock solution is required to make 20ml of a 50 μM solution?
Using the equation C1V1 = C2V2, where C1=10 mM, C2=50 μM, V2=20 ml and V1 is the unknown:
Enter 10 into the Concentration (start) box and select the correct unit (millimolar)
Enter 50 into the Concentration (final) box and select the correct unit (micromolar)
Enter 20 into the Volume (final) box and select the correct unit (milliliter)
Press calculate
The answer of 100 microliter (0.1 ml) appears in the Volume (start) box

=
/

Calculate the volume of solvent required to reconstitute your vial.

The reconstitution calculator allows you to quickly calculate the volume of a reagent to reconstitute your vial.
Simply enter the mass of reagent and the target concentration and the calculator will determine the rest.

g/mol

Enter the chemical formula of a compound to calculate its molar mass and elemental composition

Tip: Chemical formula is case sensitive: C10H16N2O2 c10h16n2o2

Instructions to calculate molar mass (molecular weight) of a chemical compound:
To calculate molar mass of a chemical compound, please enter its chemical formula and click 'Calculate'.
Definitions of molecular mass, molecular weight, molar mass and molar weight:
Molecular mass (molecular weight) is the mass of one molecule of a substance and is expressed n the unified atomic mass units (u). (1 u is equal to 1/12 the mass of one atom of carbon-12)
Molar mass (molar weight) is the mass of one mole of a substance and is expressed in g/mol.

bottom

Tech Support

Please see Inhibitor Handling Instructions for more frequently ask questions. Topics include: how to prepare stock solutions, how to store products, and cautions on cell-based assays & animal experiments, etc.

Keywords

KF38789 257292-29-8 Others inhibit Inhibitor PSGL-1 Cell adhesion P-selectin Inhibitor KF-38789 KF 38789 Inflammation inhibitor

 

TargetMol